Peripherals

Report Printer

Report Printer

The Report Printer enables you to print critical information including the Current Flow Conditions, Leak Test Results, Alarm Conditions and a complete Alarm Log of the last 256 alarm conditions.

The printer is conveniently mounted into the isolator base panel and is operated from the Isolator Control System.

The printer uses thermal printing technology which means that you do not need to load ink, toner or cartridges. It accepts industry standard 57mm paper width.

Specifications:

  • Base front panel mounted Thermal Printer.
  • Industry standard 57mm paper width.
  • All printed reports are headed with the Isolator Unit ID number, date and time and terminated with a signature box for acceptance.
  • Fan Failure, Power Failure alarms and Leak Test results are printed automatically. Other reports are printed on request.

The following reports can be printed:-

  • Current Flow Conditions
  • Fan Failure
  • Power Failure
  • Leak Test results
  • Alarm Log of the last 256 alarms (formatted to A4 length to allow simple filing and faxing)
  • Isolator parameter settings (password protected)

Remote Report Printer

Remote Report Printer

To avoid the presence of paper in the clean room the Remote Report Printer option is available as a portable printer connected by Bluetooth to the isolator.

The Report Printer enables you to print critical information including the Current Flow Conditions, Leak Test Results, Alarm Conditions and a complete Alarm Log of the last 256 alarm conditions.

The printer uses thermal printing technology which means that you do not need to load ink, toner or cartridges. It accepts industry standard 57mm paper width.

Specifications:

  • Portable Thermal Printer, battery and mains power.
  • Bluetooth connection to the isolator with 10m range in the hospital environment.
  • Industry standard 57mm paper width.
  • All printed reports are headed with the Isolator Unit ID number, date and time and terminated with a signature box for acceptance.
  • Fan Failure, Power Failure alarms and Leak Test results are printed automatically. Other reports are printed on request.

The following reports can be printed:-

  • Current Flow Conditions
  • Fan Failure
  • Power Failure
  • Leak Test results
  • Alarm Log of the last 256 alarms (formatted to A4 length to allow simple filing and faxing)
  • Isolator parameter settings (password protected)

CCTV Systems

CCTV display

Closed Circuit TV cameras can be used for training and quality control in isolators.

Amercare A2 isolators can have provision for integrating a CCTV camera into central Process Section.

Specification of the cameras need to be discussed before placing an order to ensure that they are suitable for the purpose required and that they function correctly with any exisiting systems

Typically a PTZ (Pan, Tilt, Zoom) camera is fitted and communicates to a PC / Recording Solution via a PoE connection.

Key features:

  • Fully integrated into the side wall of the process section
  • PTZ functions to enable detailed viewing of small products such as vials and syringes.

Benchtop Viewing Barrier

Benchtop Viewing Barrier

The Amercare Benchtop Viewing Barrier provides additional radiation protection to the operator when handling radioactive material.

The angled front face of the barrier is fitted with a lead glass panel; this offers protection to the user without obscuring their view.

The viewing barrier is made with a satin bead blast stainless steel outer skin with a polished stainless steel inner skin. The viewing barrier is fitted with plastic feet that provides a stable platform.

Both the base and angled front face incorporate 13mm of lead shielding. The lead glass panel is made from 13mm thick RW46 Lead Glass.

Benchtop Viewing Barrier2
Weight = 20kg
Benchtop Viewing Barrier stats
Lead Equivalent of RW46 Glass (Thickness 13mm)

Isolator Viewing Barrier

Isolator Viewing Barrier

The Amercare Isolator Viewing Barrier provides additional radiation protection to the operator when handling radioactive material.

The angled front face of the barrier is fitted with a lead glass panel; this offers protection to the user without obscuring their view.

Made with a satin bead blast stainless steel outer skin with a polished stainless steel inner skin the barrier is also fitted with plastic feet that provides a stable platform. Both the base and angled front face incorporate 13mm of lead shielding. The lead glass panel is made from 13mm thick RW46 Lead Glass.

Isolator Viewing Barrier2
Weight - 25kg
Benchtop Viewing Barrier stats
Lead Equivalent of RW46 Glass (Thickness 13mm)

Extract Fan for Negative and Positive Pressure Isolators

Negative Pressure Isolator Extract Fan
Negative Pressure
Positive Pressure Isolator Extract Fan
Positive Pressure

Amercare isolators can be supplied with a remote extract fan. The fans are made from an all polypropylene moulded construction and are designed to be resistant to a wide range of corrosive fumes and liquids.

As standard the fans comes supplied mounted onto a plastic weather pedestal for installations on roof tops. They also come fitted with an electrical isolator, anti-vibration mounts and a drain for the pedestal. The Positive Pressure Fan is also available mounted to a metal bracket as shown opposite.

The motor powering the extract fans are a direct drive single phase model with an IP54 / IP55 rating.

Key features:

  • Corrosion resistant
  • All moulded polypropylene construction
  • Suitable for external use
  • No routine maintenance required
  • LG0 Handing as standard

Options:

  • Single or Three Phase Versions
  • Invertor driven
  • Various ‘handings’
  • 110V version available

Continuous Particle Monitoring

This option is available on all Amercare isolators and allows for connection of the isolator’s main processing chamber to a particle counter to continuously monitor in use particle levels.

The system consists of an isokinetic sampling head, a fixed support (that can be made removeable if required) and an automated shut off valve to enable leak testing of the isolator.

The particle counter is mounted within the baseframe, below the Isokinetic Sampling Head to minimise the length of tubing.

The particle counter can be accessed via a separate access plate on the front of the baseframe.

The CPM system is compatible with many different manufacturers 1cfm particle counting systems.

Key features:

  • Stainless Steel Isokinetic sampling head
  • Flexible support to allow for repositioning
  • Automated Shut off valve for leak testing
  • Compatible with many different manufacturers 1cfm counters

Isolator Bypass Valve

Isolator Bypass Valve
Normal Running Configuration
Isolator Bypass Valve2
Leak Testing Configuration

All Amercare isolators can be fitted with an optional Bypass Valve.

This valve is designed so that when isolator leak tests are carried out the air that normally passes through the isolator and into the extract duct during normal operation passes straight into the extract duct. This means that the room pressures are not affected during the leak test due to the change in air extract volume.

Changes in room pressures can have a major effect on leak test results.

Key features:

  • Works on all designs of isolators
  • Can be retrofitted on existing isolators
  • Low cost
  • Simple to use
  • Integrated baffle to adjust extract flow when bung removed

Calibrator Autodipper

Calibrator Autodipper

All Amercare Radiopharmacy Isolators have the option to be fitted with a Calibrator Autodipper.

When fitted the Autodipper assembly moves a bobbin that carriers either a vial or syringe containing the sample that that requires its activity measuring via the Ionization Chamber. Automating this process with help reduce hand dose to the operator(s).

The movement of the bobbin is controlled by a foot operated switch meaning that there is no need to remove your hands for the gloves to operate the autodipper. The system is designed so that through the use of different inserts a wide range of either vials or syringes can be safely located in the bobbin.

The Calibrator Autodipper can be retrofitted to existing Radiopharmacy Isolators.

Key features:

  • Helps in reducing hand dose to operators
  • Compatible with a wide range of vials and syringes
  • Foot operated
  • Easy to use
  • Can be retrofitted onto existing Radiopharmacy isolators
  • Can be retrofitted on existing isolators
  • Low cost
  • Simple to use
  • Integrated baffle to adjust extract flow when bung removed

Premac® (Lead Acrylic) Panels

Premac Lead Acrylic Panels

Amercare RadioPharmacy isolators are available with the option of fitting Premac® (Lead Acrylic) Glove Port panels in place of the stand acrylic items.

The Premac panels are available in a 46mm thicknesses. Premac® lead acrylic is a lead loaded acrylic copolymer resin with particular shielding properties. The material is transparent with a very light brown tint, exhibiting virtually all the normal chemical and physical properties of conventional acrylic.

Key features:

  • Panels available for any isolator section
  • 46mm thick offering equivalent of 2.2mm lead Radiation protection to the operator

Integrated Heater Chiller

Integrated Heated Chiller
Integrated Heated Chiller2

Amercare Heater Chiller Well is a 300mm x 200mm x 200mm well chamber integrated into the base of the isolator. Temperature control is by means of solid state Peltier type thermo electric devices which allow the Well temperature to be set anywhere in the range -5°C to +40°C.

The Well and the Well lid are fully insulated to maintain an even temperature with minimal heat loss and to minimise condensation during chilling operations. The Well lid is stainless steel and is fully flush with the isolator floor. The lid is removed using a magnetic handle. The handle can be easily removed such that the isolator floor can be used for normal operations even over the Well position.

Items can be placed directly into the well, or Amercare can supply custom designed and made blocks for customers tube/vessel requirements.

Specifications:

Integrated Heater Chiller

Glove Leak Tester

Glove Leak Tester

The Amercare Glove Leak Tester has been designed so that operators can quickly and easily check that there are no leaks in the fitted gauntlets / sleeve-gloves.

This enables the operator to ensure that the isolator’s process chamber integrity is not being compromised by leaks in the fitted gauntlets / sleeves.

Specifications:

The Glove Leak Tester comes in a range of sizes – 150mm (6”), 200mm (8”), 250mm (10”) and 300mm (12”).

Hanging Rail

Hanging Rail

All Amercare isolators can be fitted with a hanging rail.

This all Stainless Steel items comes as standard with 6 hooks to enable the operator to hang up bags or other items quickly and conveniently.

CONTACT OUR SALES TEAM FOR ASSISTANCE AND TO PLACE AN ORDER